<%NUMBERING1%>.<%NUMBERING2%>.<%NUMBERING3%> PRTG Manual: Dell EMC Unity Storage Pool v2 Sensor

The Dell EMC Unity Storage Pool v2 sensor monitors a storage pool on a Dell EMC storage system via the Representational State Transfer (REST) application programming interface (API).

Dell EMC Unity Storage Pool v2 Sensor

Dell EMC Unity Storage Pool v2 Sensor

i_square_cyanFor a detailed list and descriptions of the channels that this sensor can show, see section Channel List.

Sensor in Other Languages

  • Dutch: Dell EMC Unity Storage Pool v2
  • French: Dell EMC Unity Storage Pool v2
  • German: Dell EMC Unity Storage Pool v2
  • Japanese: Dell EMC Unity Storage Pool v2
  • Portuguese: Dell EMC Unity Storage Pool v2
  • Russian: Dell EMC Unity Storage Pool v2
  • Simplified Chinese: Dell EMC Unity Storage Pool v2
  • Spanish: Dell EMC Unity Storage Pool v2

Remarks

  • This sensor requires credentials for Dell EMC in settings that are higher in the object hierarchy, for example, in the settings of the parent device.
  • This sensor only supports systems from the Dell EMC Unity family with Unity OE 5.x.
  • Dell EMC systems that provide a REST API are EMC Unity Family, EMC Unity All Flash, EMC Unity Hybrid, and EMC UnityVSA.
  • This sensor supports the IPv6 protocol.
  • This sensor has a very low performance impact.
  • This sensor uses lookups to determine the status values of one or more channels. This means that possible states are defined in a lookup file. You can change the behavior of a channel by editing the lookup file that the channel uses. For details, see section Define Lookups.

Add Sensor

The Add Sensor dialog appears when you manually add a new sensor to a device. It only shows the settings that are required to create the sensor. You can change nearly all settings on the sensor's Settings tab after creation.

PRTG performs a meta-scan before you can add this sensor and requires basic information in advance. Provide the required information in the dialog box that appears. PRTG then recognizes all items that are available for monitoring based on your input.

i_round_blueThe settings that you select in the Add Sensor dialog are valid for all sensors that you create when you finish the dialog.

Dell EMC Specific

Setting

Description

Storage Pool Name

Select the storage pools that you want to monitor. PRTG creates one sensor for each storage pool that you select.

i_round_blueEnable check boxes in front of the respective lines to select the items. Use the check box in the table header to select all items or to cancel the selection. In large tables, use the search function in the upper-right corner.

Basic Sensor Settings

Click the Settings tab of a sensor to change its settings.

Basic Sensor Settings

Basic Sensor Settings

Setting

Description

Sensor Name

Enter a name to identify the sensor.

Parent Tags

Shows tags that the sensor inherits from its parent device, parent group, and parent probe.

i_round_blueThis setting is for your information only. You cannot change it.

Tags

Enter one or more tags. Confirm each tag with the Spacebar key, a comma, or the Enter key. You can use tags to group objects and use tag-filtered views later on. Tags are not case-sensitive. Tags are automatically inherited.

i_round_blueIt is not possible to enter tags with a leading plus (+) or minus (-) sign, nor tags with parentheses (()) or angle brackets (<>).

i_round_blueFor performance reasons, it can take some minutes until you can filter for new tags that you added.

The sensor has the following default tags that are automatically predefined in the sensor's settings when you add the sensor:

  • dellemc
  • dellemcpool
  • dellemcstorage
  • emcpoolsensor
  • emcsensor
  • restsensor

Priority

Select a priority for the sensor. This setting determines the position of the sensor in lists. The highest priority is at the top of a list. Choose from the lowest priority (i_priority_1) to the highest priority (i_priority_5).

i_round_blueUsually, a sensor connects to the IP Address/DNS Name of the parent device. See the device settings for details. For some sensors, you can explicitly define the monitoring target in the sensor settings.

Dell EMC Specific

Dell EMC Specific

Dell EMC Specific

Setting

Description

Storage Pool Name

Shows the name of the storage pool that this sensor monitors.

i_round_bluePRTG shows this value for reference purposes only. If you need to change this value, add the sensor anew.

Storage Pool ID

Shows the ID of the storage pool that this sensor monitors.

i_round_bluePRTG shows this value for reference purposes only. If you need to change this value, add the sensor anew.

Sensor Display

Sensor Display

Sensor Display

Setting

Description

Primary Channel

Select a channel from the list to define it as the primary channel. In the device tree, the last value of the primary channel is always displayed below the sensor's name. The available options depend on what channels are available for this sensor.

i_round_blueYou can set a different primary channel later by clicking b_channel_primary below a channel gauge on the sensor's Overview tab.

Graph Type

Define how different channels are shown for this sensor:

  • Show channels independently (default): Show a graph for each channel.
  • Stack channels on top of each other: Stack channels on top of each other to create a multi-channel graph. This generates a graph that visualizes the different components of your total traffic.
    i_round_redYou cannot use this option in combination with manual Vertical Axis Scaling (available in the channel settings).

Stack Unit

This setting is only visible if you enable Stack channels on top of each other as Graph Type. Select a unit from the list. All channels with this unit are stacked on top of each other. By default, you cannot exclude single channels from stacking if they use the selected unit. However, there is an advanced procedure to do so.

Debug Options

Debug Options

Debug Options

Setting

Description

Result Handling

Define what PRTG does with the sensor result:

  • Discard result: Do not store the sensor result.
  • Store result: Store the last sensor result in the \Logs\sensors subfolder of the PRTG data directory on the probe system. The file name is Result of Sensor [ID].log. This setting is for debugging purposes. PRTG overwrites this file with each scanning interval.

i_podThis option is not available when the sensor runs on the hosted probe of a PRTG Hosted Monitor instance.

i_round_blueIn a cluster, PRTG stores the result in the PRTG data directory of the master node.

Inherited Settings

By default, all of these settings are inherited from objects that are higher in the hierarchy. We recommend that you change them centrally in the root group settings if necessary. To change a setting for this object only, click b_inherited_enabled under the corresponding setting name to disable the inheritance and to display its options.

i_square_cyanFor more information, see section Inheritance of Settings.

Scanning Interval

i_round_blueThe minimum scanning interval of this sensor is 1 minute.

i_round_blueThe recommended scanning interval of this sensor is 5 minutes.

Scanning Interval

Scanning Interval

i_square_cyanFor more information, see section Root Group Settings, section Scanning Interval.

Schedules, Dependencies, and Maintenance Window

i_round_blueYou cannot interrupt the inheritance for schedules, dependencies, and maintenance windows. The corresponding settings from the parent objects are always active. However, you can define additional schedules, dependencies, and maintenance windows. They are active at the same time as the parent objects' settings.

Schedules, Dependencies, and Maintenance Window

Schedules, Dependencies, and Maintenance Window

i_square_cyanFor more information, see section Root Group Settings, section Schedules, Dependencies, and Maintenance Window.

Access Rights

Access Rights

Access Rights

i_square_cyanFor more information, see section Root Group Settings, section Access Rights.

Channel Unit Configuration

i_round_blueWhich channel units are available depends on the sensor type and the available parameters. If no configurable channels are available, this field shows No configurable channels.

Channel Unit Configuration

Channel Unit Configuration

i_square_cyanFor more information, see section Root Group Settings, section Channel Unit Configuration.

Channel List

i_round_blueWhich channels the sensor actually shows might depend on the target device, the available components, and the sensor setup.

Channel

Description

Downtime

In the channel table on the Overview tab, this channel never shows any values. PRTG uses this channel in graphs and reports to show the amount of time in which the sensor was in the Down status

Free Size

The free size

Free Size %

The free size (%)

i_round_blueThis channel has default limits:

  • Lower warning limit: 25%
  • Lower error limit: 10%

Health Status

The health status

  • Up status: OK, OK But Minor Warning
  • Warning status: Degraded, Minor Issue
  • Down status: Major Issue, Critical Issue, Non Recoverable
  • Unknown status: Unknown

i_round_blueThis channel is the primary channel by default.

Metadata Subscribed Size

The subscribed metadata size

Metadata Used Size

The used metadata size

Preallocated Size

The preallocated size

Preallocated Size %

The preallocated size (%)

Snapshot Subscribed Size

The subscribed snapshot size

Snapshot Used Size

The used snapshot size

Subscribed Size

The subscribed size

Subscribed Size %

The subscribed size (%)

Total Size

The total size

Used Size

The used size

Used Size %

The used size (%)

More

i_square_blueKNOWLEDGE BASE

What security features does PRTG include?