<%NUMBERING1%>.<%NUMBERING2%>.<%NUMBERING3%> PRTG Manual: Redfish Power Supply Sensor
The Redfish Power Supply sensor monitors the power supply of a Redfish Scalable Platforms Management API (Redfish)-capable server.
Redfish Power Supply Sensor
For a detailed list and descriptions of the channels that this sensor can show, see section Channel List.
Sensor in Other Languages
Dutch: Redfish Power Supply
French: Redfish Power Supply
German: Redfish Power Supply
Japanese: Redfish Power Supply
Portuguese: Redfish Power Supply
Russian: Redfish Power Supply
Simplified Chinese: Redfish Power Supply
Spanish: Redfish Power Supply
Remarks
This sensor requires credentials for Redfish in settings that are higher in the object hierarchy, for example, in the settings of the parent device.
This sensor supports the IPv6 protocol.
This sensor has a very low performance impact.
This sensor uses lookups to determine the status values of one or more channels. This means that possible states are defined in a lookup file. You can change the behavior of a channel by editing the lookup file that the channel uses. For details, see section Define Lookups.
Supporters of the Redfish standard are Broadcom, Dell, Emerson, HPE, Intel, Lenovo, Microsoft, Supermicro, and VMware.
Add Sensor
The Add Sensor dialog appears when you manually add a new sensor to a device. It only shows the settings that are required to create the sensor. You can change nearly all settings on the sensor's Settings tab after creation.
PRTG performs a meta-scan before you can add this sensor and requires basic information in advance. Provide the required information in the dialog box that appears. PRTG then recognizes all items that are available for monitoring based on your input.
The settings that you select in the Add Sensor dialog are valid for all sensors that you create when you finish the dialog.
Redfish Specific
Setting
Description
Name
Select the power supplies that you want to monitor. PRTG creates one sensor for each power supply that you select.
Enable check boxes in front of the respective lines to select the items. Use the check box in the table header to select all items or to cancel the selection. In large tables, use the search function in the upper-right corner.
Basic Sensor Settings
Click the Settings tab of a sensor to change its settings.
If the name contains angle brackets (<>), PRTG replaces them with braces ({}) for security reasons. For more information, see the Knowledge Base: What security features does PRTG include?
This setting is for your information only. You cannot change it.
Tags
Enter one or more tags. Confirm each tag with the Spacebar key, a comma, or the Enter key. You can use tags to group objects and use tag-filtered views later on. Tags are not case-sensitive. Tags are automatically inherited.
It is not possible to enter tags with a leading plus (+) or minus (-) sign, nor tags with parentheses (()) or angle brackets (<>).
For performance reasons, it can take some minutes until you can filter for new tags that you added.
The sensor has the following default tags that are automatically predefined in the sensor's settings when you add the sensor:
redfish
powersupply
Priority
Select a priority for the sensor. This setting determines the position of the sensor in lists. The highest priority is at the top of a list. Choose from the lowest priority () to the highest priority ().
Redfish Specific
Redfish Specific
The information in the Redfish Specific settings reflect the status of the system at the time of sensor creation. If any setting changes after creation, the Redfish Specific settings do not reflect the change. Add the sensor anew to update the displayed settings.
Setting
Setting
Name
Shows the name of the power supply that this sensor monitors.
PRTG shows this value for reference purposes only. If you need to change this value, add the sensor anew.
Model
Shows the model of the power supply that this sensor monitors.
PRTG shows this value for reference purposes only. If you need to change this value, add the sensor anew.
Manufacturer
Shows the manufacturer of the power supply that this sensor monitors.
PRTG shows this value for reference purposes only. If you need to change this value, add the sensor anew.
Serial Number
Shows the serial number of the power supply that this sensor monitors.
PRTG shows this value for reference purposes only. If you need to change this value, add the sensor anew.
Sensor Display
Sensor Display
Setting
Setting
Primary Channel
Select a channel from the list to define it as the primary channel. In the device tree, the last value of the primary channel is always displayed below the sensor's name. The available options depend on what channels are available for this sensor.
You can set a different primary channel later by clicking below a channel gauge on the sensor's Overview tab.
Graph Type
Define how different channels are shown for this sensor:
Show channels independently (default): Show a graph for each channel.
Stack channels on top of each other: Stack channels on top of each other to create a multi-channel graph. This generates a graph that visualizes the different components of your total traffic. You cannot use this option in combination with manual Vertical Axis Scaling (available in the channel settings).
Stack Unit
This setting is only visible if you enable Stack channels on top of each other as Graph Type. Select a unit from the list. All channels with this unit are stacked on top of each other. By default, you cannot exclude single channels from stacking if they use the selected unit. However, there is an advanced procedure to do so.
Debug Options
Debug Options
Setting
Description
Result Handling
Define what PRTG does with the sensor result:
Discard result: Do not store the sensor result.
Store result: Store the last sensor result in the \Logs\sensors subfolder of the PRTG data directory on the probe system. The file names are Result of Sensor [ID].txt and Result of Sensor [ID].Data.txt. This setting is for debugging purposes. PRTG overwrites these files with each scanning interval.
This option is not available when the sensor runs on the hosted probe of a PRTG Hosted Monitor instance.
In a cluster, PRTG stores the result in the PRTG data directory of the master node.
Inherited Settings
By default, all of these settings are inherited from objects that are higher in the hierarchy. We recommend that you change them centrally in the root group settings if necessary. To change a setting for this object only, click under the corresponding setting name to disable the inheritance and to display its options.
For more information, see section Root Group Settings, section Scanning Interval.
Schedules, Dependencies, and Maintenance Window
You cannot interrupt the inheritance for schedules, dependencies, and maintenance windows. The corresponding settings from the parent objects are always active. However, you can define additional schedules, dependencies, and maintenance windows. They are active at the same time as the parent objects' settings.
Schedules, Dependencies, and Maintenance Window
For more information, see section Root Group Settings, section Schedules, Dependencies, and Maintenance Window.
Access Rights
Access Rights
For more information, see section Root Group Settings, section Access Rights.
Channel Unit Configuration
Which channel units are available depends on the sensor type and the available parameters. If no configurable channels are available, this field shows No configurable channels.
Channel Unit Configuration
For more information, see section Root Group Settings, section Channel Unit Configuration.
Channel List
Which channels the sensor actually shows might depend on the target device, the available components, and the sensor setup.
Channel
Description
Downtime
In the channel table on the Overview tab, this channel never shows any values. PRTG uses this channel in graphs and reports to show the amount of time in which the sensor was in the Down status
Input Voltage
The input voltage
Input Watts
The input watts
Output Load
The output load
This channel has default limits:
Upper warning limit: 90%
Upper error limit: 99%
Output Watts
The output watts
Power Efficiency
The power efficiency
Power Supply Status
The power supply status
Up status: OK
Warning status: Warning
Down status: Critical
Unknown status: Offline / Absent
This channel is the primary channel by default.
More
KNOWLEDGE BASE
I want to know which of my systems support the PRTG Redfish sensors. Can you help me?